Sports- and exercise lighting

» BANDY FIELDS AND ICE RINKS
» FOOTBALL FIELDS AND SPORTS FIELDS
» MULTI-SPORTS ARENA
» INDOOR SPORTS VENUES
» SKI GATE FACILITIES
» SKI AND ELECTRIC LIGHT TRACKS
» TROT TRACKS
» SPEEDWAY TRACKS
» GO-KARTING TRACKS

MODERN LIGHTING FOR ASSOCIATIONS AT ALL LEVELS

Sports- og exercise lighting is to make facilities flexible and attractive by providing opportunities for activity and movement during the darker hours of the day. Facilities are used for many different sports and the focus is on making the lighting functional for both practitioners and spectators, we are convinced that good lighting can attract new members and sponsors for clubs at all levels. For the practitioner, good lighting enhances the experience and many times good visibility is a requirement, therefore minimal glare is important. This type of facility can often be located close to residential areas and spill light must therefore be carefully controlled.

LIGHTING FOR SPORT AND EXERCISE TAKES INTO ACCOUNT:

» OUTDOOR ENVIRONMENTS - The physical design of luminaires is of utmost importance as luminaires in outdoor environments are exposed to enormous external impact and risk of vandalism. High quality floodlights should have a high Ingress Protection (IP) and vandal class (IK). The luminaire housing should have effective heat dissipation with substantial heat sinks and be made of corrosion resistant material with oven cured powder coating. A five-year warranty provides the basis for trouble-free and safe operation of the system.

»SITE DESIGN - Each facility is unique and it is important to position lighting so that it does not interfere with either performers or spectators and that other external influences can be minimised.

» LIGHTING REQUIREMENTS - Lighting recommendations determine the lighting needs of a sports & leisure facility. Higher divisions have higher lighting requirements. The contracting entity defines a requirement specification for the facility such as how much lighting is needed and what level of uniformity is required.

» COMFORTABLE AND GLARE-FREE LIGHTING -
Light point height and luminaire angle are of utmost importance when planning the facility. For best lighting comfort, masts or columns at heights of 6-42m, maximum luminaire angle 20 degrees from the horizontal plane and effects adjusted as required are recommended. Asymmetrical light patterns are widely used for lighting sports & exercise facilities. Installations in residential areas need to be extremely careful - no one wants complaints from nearby residents.

» MINIMISED LIGHT DISTURBANCE - Good shielding and thoughtful luminaire design are required to eliminate light scattering upwards from the luminaire. The night sky should be preserved as light pollution is believed to affect species and ecosystem functions.

Savings in maintenance, energy consumption and time

Long lifetimes and the ability to integrate smart control systems contribute to low maintenance and energy costs. Today, it is not difficult to justify a switch from traditional floodlights to modern technology, as modern LED technology allows for lower effects thanks to higher light output. Our luminaires are equipped with the latest technology and deliver lumen/W in absolute top class. In many cases, this allows installations to be designed with fewer floodlights than the equivalent traditional solution.

Another great advantage is that the floodlights can be used as needed without any warm-up times. With our solutions, associations and practitioners can benefit from high quality light and instant light impact at the touch of a button, no time is wasted waiting for the luminaires' light sources to heat up.

High quality and optimal light comfort in all situations

With nearly 20 years of experience in lighting for sports & leisure facilities, we have developed customised floodlights with efficient optics to handle the high demands for light comfort and uniformity. An optimised light pattern benefits not only employees and customers, but also nearby buildings, roads and the natural environment around illuminated sites. The right luminaire with the right optics places light where it is needed without discomfort glare and contributes to minimised light pollution. To ensure maximum light comfort and uniformity, we make sure to use custom optics and the right luminaire angles.

We tailor the installation

There are many parameters involved in planning a lighting system for large areas. These range from potential obstructions to appropriate mast heights, luminaire angles and mounting devices. Our skilled consultants will assist with lighting calculations free of charge.

Standard solutions football

Here are some of our standard packages for football facilities. However, each
facility is unique and the requirements determine the total cost of lighting.

7-MAN PITCH - 100 LUX

50 x 30 METER - 4 MASTER

" 8 pcs SAFIR 4 375 W (F1) incl. bolt kit
" 4 pcs LIGHT MAST 340, 230 12 m incl. V-foundation
" 4 pcs Climbing protection 340 x 2.5 m incl. pop rivet
" 4 pcs Headlight beam 2 m incl. bolt kit
" 4 pcs Fuse box incl. 8 pcs automatic fuse 10 A

LIGHTING EFFICIENCY > 100 lx
UNIFORMITY 0.69 U0
TOTAL POWER 3 kW

9-MAN PITCH - 100 LUX

65 x 50 METER - 4 MASTER

" 8 pcs PRECISION 1 650 W (F1/F3) incl. bolt kit
" 4 pcs LIGHT MAST 450, 340, 230 15 m incl. V-foundation
" 4 pcs Climbing protection 450 x 2.5 m incl. pop rivet
" 4 pcs Headlight beam 2 m incl. bolt set
" 4 pcs Fuse box incl. 8 pcs automatic fuse 10 A

Illumination power > 100 lx
UNIFORMITY 0.66 U0
TOTAL POWER 5.2 kW

11-MAN PITCH - 200 LUX

105 x 65 METER - 6 MASTER

" 12 pieces PRECISION 3 1670 W (F2/F3) incl. bolt kit
" 6 pcs LIGHT MAST 450, 340, 230 18 m incl. V-foundation
" 6 pcs Climbing protection 450 x 2.5 m incl. pop rivet
" 6 pcs Headlight beam 2 m incl. bolt kit
" 6 pcs Fuse box incl. 12 pcs automatic fuse 16 A

Illumination power > 200 lx
UNIFORMITY 0.70 U0
TOTAL POWER 20 kW

11-MAN PITCH - 400 LUX

105×65 METERS - 6 MASTS

" 24 pcs PRECISION 3 1670 W (F2/F3) incl. bolt kit
" 6 pcs LIGHT MAST 690, 560, 450 18 m incl. V-foundation
" 6 pcs Climbing protection 690 x 2.5 m incl. pop rivet
" 6 pcs Headlight beam 3 m incl. bolt kit
" 6 pcs Fuse box incl. 24 pcs automatic fuse 16 A

Illumination power > 400 lx
UNIFORMITY 0.76 U0
TOTAL POWER 40 kW